Home / Services / Fire Inspections & Testing
Annual inspections. Testing. Records.
Annual fire protection inspections and testing in Toronto
FC Fire Prevention carries out the annual inspections and tests the Ontario Fire Code requires for fire alarms, sprinkler systems, portable extinguishers, emergency lighting and kitchen suppression in commercial buildings, condominiums, apartment buildings and restaurants across Toronto and the GTA. Most clients combine the systems into one planned visit so access is arranged once, the reports arrive together, and the deficiencies are followed up as one list.
Technical review: Paul Christofi, Fire Protection Engineering Technician (Seneca College), CFAA Registered Fire Alarm Technician, updated 23 October 2026.

The systems, the standards and how often
| System | Standard the Fire Code applies | Routine tasks | Annual or periodic work |
|---|---|---|---|
| Fire alarm | CAN/ULC-S536-2019 | Daily panel check; monthly device tests | Annual device-level inspection and test |
| Sprinklers, standpipes and fire pumps | NFPA 25 | Weekly and monthly checks of valves, gauges and pump status, depending on the system | Quarterly and annual tests; five-year internal inspections and the other multi-year items, all performed by FC Fire |
| Portable extinguishers | NFPA 10 | Monthly visual check | Annual maintenance and tagging; six-year internal examination and hydrostatic testing on the intervals the standard sets for each type (we supply replacements; we do not recharge) |
| Emergency lighting and exit signs | Ontario Fire Code requirements and the design duration | Monthly check and functional test | Annual test for the full duration the design requires, which is not always 30 minutes, with charging-system checks afterwards |
| Kitchen suppression | NFPA 96 and the manufacturer’s manual | Visual checks by kitchen staff | Semi-annual service and inspection; coordination with hood cleaning |
| Special hazard systems | The system’s listing and manufacturer’s manual | As specified | As specified |
Frequencies depend on the building and the installed equipment; the current Ontario Fire Code (O. Reg. 213/07 as amended, including the amendments in force from 1 January 2026) is the legal reference, and we confirm the applicable schedule for your systems in the quote.
Your contractor’s inspection and the fire department’s inspection are different visits
We test and maintain the equipment within a booked scope and give you technical reports. A Toronto Fire Services inspector assesses fire safety in the building and can issue directions or orders; our reports are the evidence you keep for that visit, but they do not replace it. If you have received a notice or order, our inspection-order reviews and the Toronto Fire Inspection Help tool explain the next steps. The 2026 annual inspection guide covers both visits in detail.
What you receive
- A report for each system with the equipment inventory, results, deficiencies and their locations, and anything that could not be accessed or tested, with the reason.
- Service tags where the standard uses them.
- A single deficiency list across systems, with a recommendation for each item: repair, replace, investigate or monitor.
- Records in a form you can file with the Fire Safety Plan, send to your insurer or show a fire inspector.
Who performs the work
Inspections are carried out by Paul Christofi and Wais Faizi. Paul Christofi, who leads FC Fire’s technical work, holds a Fire Protection Engineering Technician diploma from Seneca College, a CFAA registration valid to July 2027, and certification in kitchen fire suppression system inspection, and previously worked as a fire inspector with the Toronto Transit Commission. FC Fire Prevention Inc. was founded in 2022, is BBB accredited with an A+ rating, and is rated 5.0 on Google from 28 reviews.
Before the visit
Send the property address and use, the systems to include, previous reports and outstanding findings, access restrictions and an on-site contact. The one-page inspection preparation worksheet (fillable PDF) organizes this; it is a planning aid, not a compliance checklist. We agree the equipment list and the quantities (from a previous report or to be confirmed on site), who to call if the team finds unlisted equipment, which parts of the visit depend on residents or other contractors, and how untested items will be handled.
After the visit
Review the findings with us, decide which items to repair now, and keep the corrective-work records with the original finding so the history stays clear. Repairs are quoted separately and can include retesting where the work needs it. For an example, an annual inspection at a North York commercial property identified work across the fire alarm, extinguishers, fire hoses, emergency lighting and sprinkler systems; FC Fire coordinated the repairs and the remaining tests with the property representative, follow-up testing found an emergency lighting unit that needed replacement, and completion was confirmed in June 2026 with the test report, a fire-safety record and the final invoice.
Broader assessments
Where you need more than equipment testing, we also carry out fire-safety audits and checks against the applicable Ontario Fire Code requirements, for example before a purchase, after a change of use, or to prepare for an inspection. Tell us the purpose and we will confirm what the assessment covers and what it does not.
What affects the price
The number of systems and devices, building size and the number of suites or locked areas, access and tenant notices, after-hours work, the state of existing records, and whether multi-year sprinkler or extinguisher items fall due this year. We quote a defined scope with exclusions and return-visit terms stated.
Questions to settle before confirming the quotation
Use the proposed equipment list to check that the quotation matches the visit you need. If a previous report covers several systems, identify which ones you want included now and flag anything you cannot confirm.
- Equipment list: Does the scope identify the systems, buildings and areas included? Are the quantities taken from a previous report or still to be checked?
- Additional equipment: If the team finds another system or an unlisted device, who should they contact to discuss the scope?
- Access dependencies: Does any part of the visit depend on a resident, building representative or another contractor being available?
- Follow-up: How will equipment that could not be accessed or tested be identified, and how would a return visit be arranged?
- Handover: Which reports are included, who should receive them and how will outstanding items be explained?
The inspection preparation guide helps turn these answers into a visit plan. If the enquiry involves an existing fault, describe it when discussing fire alarm service so investigation can be considered in the scope.
After the visit, use the findings and follow-up guide to identify the next action. Keep the agreed scope with the resulting inspection and service records.
Questions we are asked
Can all our systems be done in one visit?
Usually yes for a single property; larger buildings may need more than one day, and sprinkler items with multi-year intervals are scheduled when they fall due.
Are repairs included?
No; they are quoted separately so you see each item, and we tell you which findings need prompt attention.
Will you recharge our extinguishers?
No. We inspect, tag and supply replacements; recharging is not a service we offer.
What if a resident does not give access?
The devices are listed as untested with the reason and we arrange a return visit for those suites; they are never marked as passed.
Do you provide a certificate?
You receive the inspection and test reports and tags that the standards call for. Whether an authority or insurer needs a specific document depends on their request; send us the wording and we will match the record to it. See our inspection reports and records page.
Can you come urgently?
Call 647-998-3473 to discuss availability; for a fire or immediate danger call 911.
Reference notes
Background material from the previous version of this page, kept for readers who want the detail.
Before, during and after an inspection visit
Plan the visit with the building representative so the agreed equipment can be accessed and findings can be followed up. Discuss notices and coordination before any testing that may affect occupants or connected services.
| When | What to coordinate |
|---|---|
| Before the visit | Confirm the equipment scope, existing reports, access contacts and any required occupant or monitoring coordination. |
| During the visit | Have the agreed representative available for access questions and clarification of equipment locations or building records. |
| After the visit | Review what was checked, any access or testing limitations, recorded deficiencies and the next actions to discuss. |
Arrange an inspection quote.
Share your building details, the equipment to be checked and any recent service records.
Request an inspection ↗contact@fcfire.ca